The KSD309 series has the max. operating temperature (280°C) of snap-action thermostat. It suits for the high-temp. home appliances, such as oven, toaster, microwave oven etc. KSD309 series is divided into 2 sub-series: KSD309-A single body (temperature control), KSD309-C dual body (temperature control+protection).
Uses: | Temperature control / overheat protection | Application: | Heating elements such as coffee makers, ovens, dishwashers, etc. |
Housing material: | ceramic | Current: | 10A/16A |
Maximum operating temperature: | 280℃ | Temperature difference: | for reference |
Tolerance: | for reference | Minimum tolerance: | 14℃ |
Contact material: | silver | Insulation resistance: | use the insulation resistance meter to add voltage DC500V, >10M. |
Electrical strength: | The part between live parts and non-charged parts can withstand 2000V (reinforced insulation type: 3750V), 50Hz AC current, sine wave, one-minute bearing test. No breakdown, no arcing. | ||
Reset type: | Manual / Auto | ||
Resistance between terminals: | ≦80mΩ | T Max: | 330°C |
Temperature characteristics: | regular type - the disconnection temperature is higher than the on temperature. (Normally closed); Type K - Disconnect temperature is lower than the on temperature. (Normally open); One-time action type - The temperature controller is turned on at room temperature, and the thermostat cannot be reset after it is disconnected. | Certification: | CQC/TUV |
Terminal model: | customized (for reference) | Cover: | Customized (for reference) |
●High precision; ●Fast heat transfer; ●High durability; ●No breakdown, no arcing; ●Each thermostat will be tested and the temperature pass rate is high. |
OT range | Life cycles | 250V 10A | 250V 16A |
60~210°C | 100,000 | CQC: 14002120139 VDE: | |
30,000 | CQC: 14002120139 VDE: | ||
211~280°C | CQC: 14002120139 VDE |
package | 500/ inner box, box size: 480 (length) * 282 (width) * 218 (height) (mm) |
minimal order size | 1000 |
payment method | Wire transfer, Western Union |
delivery time | 15 to 20 days |
Installation and use instructions: |
1. Grounding method: Connected to the grounding metal parts of the equipment through the metal casing of the thermostat. 2. The thermostat shall be operated in a general indoor environment where the relative humidity of the air is not more than 90%, no corrosive gas, no flammable gas and conductive dust. 3. When the temperature controller is in contact with the temperature, the cover should be placed close to the heat-generating part of the controlled appliance, and the thermal surface of the cover should be coated with thermal grease or other similar heat-conducting medium. 4. When the temperature controller is exposed to liquid or steam, it is recommended to use a stainless steel cover and a reliable leak-proof measure to prevent liquid from seeping into the insulation of the thermostat. 5. It is not possible to collapse or deform the top of the cover to avoid changes in operating temperature or other properties. 6. Do not allow liquid to penetrate inside the thermostat! The housing must be protected from excessive forces to prevent cracking; the housing should be kept clean to prevent contamination of conductive materials to prevent short-circuit breakdown due to reduced insulation. 7. The terminal cannot be bent during use, otherwise the reliability of the electrical connection will be affected. |