KSD301-M series thermostat is a type of water proof thermostat, it has more water proof component than the other KSD301 series products, the protection class of main body is up to IP57, it is suitable for working in the wet conditions of appliances.
Uses: | Overheat protection,waterproof | Application: | Soymilk / water dispenser / refrigerator / etc. |
Housing material: | Bakelite | Current: | 10A |
Maximum operating temperature: | 145℃ | Tmax. : | 185℃ |
Protection level: | IP54 | ||
Insulation resistance in water: | With a DC500V megger in water, the tested value is over 100MW. | Class of temperature characteristics: | Auto-reset, normal close and normal open |
●Easy to install; ●High precision; ●Fast heat transfer; ●High durability; ●No breakdown, no arcing; ●Each thermostat will be tested and the temperature pass rate is high. |
最高 OT | 寿命次数 | 250V 10A | 125V 16A |
105°C | 100,000 | UL: E137238, sec. 2 | UL: E137238, sec. 2 |
145°C | 10,000 | CQC: 12002080177 | |
100,000 | TUV: R50254301 |
package | 200/ inner box, 5 boxes/carton, box size: 480 (length) * 282 (width) * 218 (height) (mm) |
minimal order size | 1000 |
payment method | Wire transfer, Western Union |
delivery time | 15 to 20 days |
Installation and use instructions: |
1. Grounding method: Connected to the grounding metal parts of the equipment through the metal casing of the thermostat. 2. The thermostat shall be operated in a general indoor environment where the relative humidity of the air is not more than 90%, no corrosive gas, no flammable gas and conductive dust. 3. When the temperature controller is in contact with the temperature, the cover should be placed close to the heat-generating part of the controlled appliance, and the thermal surface of the cover should be coated with thermal grease or other similar heat-conducting medium. 4. When the temperature controller is exposed to liquid or steam, it is recommended to use a stainless steel cover and a reliable leak-proof measure to prevent liquid from seeping into the insulation of the thermostat. 5. It is not possible to collapse or deform the top of the cover to avoid changes in operating temperature or other properties. 6. Do not allow liquid to penetrate inside the thermostat! The housing must be protected from excessive forces to prevent cracking; the housing should be kept clean to prevent contamination of conductive materials to prevent short-circuit breakdown due to reduced insulation. 7. The terminal cannot be bent during use, otherwise the reliability of the electrical connection will be affected. |